The following Honeywell (Ademco) Manuals are available in PDF format for your review. No password or user name is required to review these manuals. If you have any questions, please call us at (800) 889-4471 Recent Customer Testimonial - 'Service is good - prices are great - callbacks are prompt - corrections are taken care of immediately. View and Download Ademco Vista-20P user manual online. Security Systems. Vista-20P Security System pdf manual download. Also for: Vista-20pcn, Vista-15p, Vista-15pcn. Refer to the User Setup chart at the back of this manual for factory defaults of user attributes and to keep a record of user programming. NOTE: Partition Master codes (VISTA-20P/PS Series only) apply only to those user numbers previously assigned (by the system master/installer) to the partition master’s partition. The Honeywell VISTA-20P is an alarm control panel and a member of the Honeywell VISTA Series of security systems. This workhorse of a panel has been around for a very long time, once being under known as the ADEMCO VISTA 20P. Honeywell VISTA-20P User Manual Leave a reply Read online Honeywell VISTA-20P User Manual with better navigation.Printable and download Honeywell VISTA-20P User Guide Pdf.
Size:Download
9,67$ 3 36 6HULHV
9,67$ 3 6HULHV
6HFXULW 6VWHPV
8VHU*XLGH
®
IMPORTANT!
PROPER INTRUSION PROTECTION
For proper intrusion coverage, sensors should be located at every possible point of entry to a home or commercial premises. This would include any skylights that may be present, and the upper windows in a
In addition, we recommend that radio backup be used in a security system so that alarm signals can still be sent to the Central Monitoring Station in the event that the telephone lines are out of order (alarm signals are normally sent over the phone lines).
EARLY WARNING FIRE DETECTION
Early warning fire detection is important in a home. Smoke and heat detectors have played a key role in reducing fire deaths in the United States. With regard to the number and placement of smoke/heat detectors, we subscribe to the recommendations contained in the National Fire Protection Association's National Fire Alarm Code (NFPA 72). These recommendations can be found on page 47 of this manual.
$ERXW 7KLV 0DQXDO
This manual is a
– 2 –
System Overview
Introduction
Congratulations on your ownership of an ADEMCO Security System. You've made a wise decision in choosing it, for it represents the latest in security protection technology today, and millions of premises are protected by ADEMCO systems. This system provides:
•Three forms of protection: burglary, fire* and emergency
•At least one keypad which provides control of system and displays system status
•Various sensors for perimeter and interior burglary protection
•Smoke or combustion detectors* designed to provide early warning in case of fire. Your system may also have been programmed to automatically send alarm or status messages over the phone lines to a Central Monitoring Station.
![]()
*Commercial installations and some residential systems may not include fire protection – check with your installer.
NOTE: The features and procedures described in this manual apply to both the
System Basics
Burglary Protection
•Several modes of burglary protection: Stay,
INSTANT: same as STAY, except entry delay is off Microsoft vista boot disk.
MAXIMUM: same as AWAY, except entry delay is off
•You can BYPASS selected zones while leaving the rest of the system armed.
•CHIME mode alerts you to the opening of protected doors and windows while the system is disarmed.
Fire Protection
•Fire protection is always active (if installed) and an alarm sounds if a fire condition is detected
•If necessary, you can manually initiate a fire alarm using the keypad (if programmed).
•Refer to the Fire Alarm System section for information regarding fire protection, smoke detectors and planning emergency exit routes.
Security Codes
•You were assigned a
•Use your security code when arming and disarming the system, and when performing other system functions.
•Other users can be assigned different security codes, each with different authority levels, which define the system functions a particular user can perform.
–5 –
System Overview (cont’d)
Zones and Partitions
•The system sensing devices have been assigned to various “zones,” which are specific areas of protection (e.g., front door, kitchen window, etc.).
•Zone numbers are displayed at the keypad when an alarm or trouble condition occurs on a sensor.
•Partitions
•Partitioned systems
Arming,
•The system must be armed before the burglary protection can sense intrusions.
•To arm your system, enter your user code followed by the desired arming key.
•If programmed, the [#] key can be pressed instead of entering the security code when arming the system.
•You can also use the
•To disarm the system, enter your user code, then press the [OFF] key.
Alarms
•When an alarm occurs, both the keypad and external sounders will sound, and the keypad will display the zone(s) causing the alarm.
•If your system is connected to a Central Monitoring Station, an alarm message will also be sent.
•To stop the alarm sounding, simply disarm the system.
Memory of Alarm
•When an alarm condition occurs, the keypad displays the number(s) of the zone(s) that caused the problem, and displays the type of alarm.
https://ameblo.jp/litttraccamig1971/entry-12640666884.html. •The message remains displayed even after disarming the system, but can be cleared with another “off” sequence.
Function Keys
•The “A,” “B,” “C,” and “D” keys on the keypad can be programmed to perform various functions.
•Functions include: activate a panic alarm, arm the system, provide step arming, switch lights on/off, send a message to a pager, display Time/Date, and start a programmed Macro sequence.
Phone Access
•If included, a phone module permits you to access the system via a
•When you call in, the phone module announces system status over the telephone, and you can arm/disarm the system and perform most function commands remotely using the telephone keys.
•Complete information for using these features is provided with the voice module.
System Overview (cont’d)
Paging Feature
•If programmed, the system can automatically send certain system condition messages to up to four
•The display consists of code numbers that indicate the type of condition that has occurred.
Scheduling
•Your system can be programmed to automatically perform certain functions (e.g., arm the system) at a predetermined time each day.
Using the Voice Message Center
Voice keypads feature a voice message center that lets you record and playback one message.
•The message can be up to
•The message remains in the Keypad’s memory until a new message is recorded.
•The volume control of the message is adjustable.
•Refer to the procedures below when using the Message Center functions.
Message Center Functions
![]()
About The Keypads
General Information
Your keypads allow you to control all system functions and feature the following:
•Liquid Crystal Displays (LCD) that show the nature and location of all occurrences
•
•Backlighting of the LCD display windows. Backlighting turns on when any key is pressed or when entering the premises through any assigned entry/exit door. This feature is helpful when a keypad is located in a dimly lit area.
•Some keypads have a voice feature that announces the nature and location of all system occurrences. Voice keypads also announce any faulted entry/exit or perimeter zone when Chime mode is on. Ask your installer if this option has been programmed for your system.
IMPORTANT: If the keypad beeps rapidly upon entering the premises, it indicates that an alarm has occurred during your absence and an intruder may still be on the premises. LEAVE IMMEDIATELY and CONTACT THE POLICE from a nearby safe location.
About The Keypads (cont’d)
– 9 –
About The Keypads (Cont’d)
AWAY: All burglary zones, interior and perimeter, are armed.
STAY: Perimeter burglary zones, such as protected windows and doors, are armed.
INSTANT: Entry delay is turned off:
Lit with STAY = Instant mode Lit with AWAY = Maximum mode
AWAY NIGHT NO AC
BYPASS PHONE TEST NOT READYALARM STAY CHIME BAT
FIRE CHECK INSTANT CANCELED
6150disp
BYPASS: This appears when one or more burglary protection zones have been bypassed.
NOT READY: Appears when burglary portion of the system is not ready for arming (due to open protection zones). The system is ready to arm when this message disappears and the READY indicator light comes on.
NO AC: Appears when AC power has been cut off. System is operating on backup battery power.
AC: Appears when AC power is present.
CHIME: Appears when the chime feature is activated.
BAT: Low battery condition in a wireless sensor (if zone number displayed) or low system battery (if no zone number displayed).
ALARM: Appears when an intrusion has been detected and the system is armed (also appears during a fire alarm or audible emergency alarm). Accompanied by the protection zone in alarm.
CHECK: Appears when a malfunction is discovered in the system at any time, or if an open is detected in a fire zone at any time, or a fault in a DAY/NIGHT burglary zone during a disarmed period. Accompanied by a display of zone number in trouble.
FIRE: Appears when a fire alarm is generated. Accompanied by a display of the zone in alarm.
A FIRE display also appears when a fire alarm is manually activated, accompanied by a display of emergency key zone number programmed for fire.
Honeywell Vista 20 User Manual
CANCELED: Appears when an alarm has been silenced by the Code + OFF sequence and will remain on until another Code + OFF sequence is keyed.
Vista 20p User Guide
Next >= Page 1 =1234567
Comments are closed.
|
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |